Appendix B: Equipment and Instrument Circuits
201045
tors marked with a black dot on the Hampden ACWM-100 wattmeter (Figure B.14). In the
wattmeter circuit diagrams in this lab, this connection is labeled “+”.
AMPS
VOLTS
+
Jumper
Figure B.14: Jumper on wattmeter “+” connection
To measure power on a three-phase system one could employ what is called the two wattmeter
method, in which two wattmeters are connected as shown in Figure B.15. The total three-phase
power is then given by the sum of the two wattmeter readings.
Figure B.15: Two Wattmeter Connection for Three-Phase Load
To demonstrate that the sum of the readings is the three-phase power, one can start with the defi-
nition for what each wattmeter is reading
*
1
*
2
Re
Re
ab a
cb c
W V I
W V I
Vista de pagina 56