Laboratory 10: AC Measurements
201027
Procedure:
Connect the following AC circuit.
12 V
rms
Change the load Z
L
, as follows:
1. A resistor of R = 25Ω
2. An inductor of L = 120 mH
3. A capacitor of C = 40 µF
4. R and L in series
5. R and C in series
6. R, L, and C in series
Measurements
For each of the loads listed above:
a) Measure the wattmeter reading.
b) Measure the total current.
c) Measure the voltage drop across each element.
For loads 4-6 also measure the current phase shift. This is done by using the oscilloscope to
measure the voltage waveform shift across the resistor on Channel 2 versus the source voltage on
Channel 1. The resistor must be the last element in the series combination for the measurement
to work properly.
Laboratory Notebook:
1. For each step compute the impedance and power factor for the load. Tabulate the measured
and computed data.
2. Construct a phasor diagram, to scale, for each of the steps. Show all currents and voltages on
each diagram in their correct relative orientations. In parts 4-6 show that the line voltage is
the phasor sum of the voltage drops across the elements of the circuit.