Rounding: to 4 digits
Command Type: Setting or Query
Setting
Syntax: TRAte<ws><value>[units]
TRAte<ws>MINimum|MAXimum
Examples: TRAte 10E-6
TRAte MIN
Query
Syntax: TRAte?[<ws>MINimum|MAXimum]
Response: NR3
Examples: TRAte?
TRAte? MIN
ERRor?
This query returns the first entry in the error queue, and
removes that entry from the queue.
Command Type: Query only
Query
Syntax: ERRor?
Response: <Error number>, "<error description>"